Skip to main content

sound:compute 1/3-octave levels from PSD (ANSI S1.11-1986)

Version: 0.0.0

Description

Compute one-third-octave-band levels from a power spectral density (PSD) input, taking into account ANSI S1.11-1986 / IEC 61260:1995. The ANSI S1.11-1986 standard describes a digital filterbank to use when computing fractional-octave-band levels from a time-domain signal. This operator applies the frequency responses of these filters to the input PSD in order to simulate the application of this filterbank. Twenty-nine bands are considered whose center frequencies range between 25 Hz and 16000 Hz

Inputs

InputNameExpected type(s)Description
Pin 0
Required
psdfieldInput power spectral density (PSD) for the levels' computation, in <unit>^2/Hz

Outputs

OutputNameExpected type(s)Description
Pin 0levelsfieldOne-third-octave-band levels. The returned level unit is derived from the input PSD's unit (for example, if the PSD is in Pa^2/Hz, the levels will be returned in Pa^2).The field support contains the one-third-octave-band center frequencies.

Configurations

NameExpected type(s)Default valueDescription
mutexboolfalseIf this option is set to true, the shared memory is prevented from being simultaneously accessed by multiple threads.

Scripting

Category: sound

Plugin: sound

Scripting name: None

Full name: None

Internal name: compute_one_third_octave_levels_from_psd_ansi_s1_11_1986

License: avrxp_snd_level1

Changelog

  • Version 0.0.0: Initial release.